FLEXIBILITY &
RANGE OF OPTIONS

Boiler room heater

HOWAT

dual & triple energy

with 1 & 2 exchangers

for connection to a HEAT PUMP

HOWAT boiler-room water heaters designed for heat pumps are the ideal solution for the immediate and efficient production of domestic hot water. Their key feature is a large heat exchanger surface area, which enables optimal heat transfer from the heat pump, ensuring high efficiency and cost savings.

Available in capacities ranging from 160 to 1000 liters, with one or two heat exchangers, allowing for easy integration into any type of system (heat pump, solar collectors, or a combination of both).

Technical Specifications

  • Outer casing: special PVC & ABS covers, highly durable over time and aesthetically excellent.
  • Water storage tank: cold-rolled steel with an internal double-layer enamel coating, fired at 860°C (DIN 4753).
  • Boiler operating pressure: 8 bar/95°C; test pressure: 13 bar.
  • Heat exchangers: externally enameled, with a large surface area, suitable for connection to a boiler, solar collectors, or a combination of both.
  • Cathodic protection: magnesium anode (DIN 4753-6).
  • Thermal insulation: minimizes heat loss, maintaining the temperature of the hot water.
  • Electric heating element: port for a 1 ½’’ electric immersion heater.

With 1 Heat Exchanger

for connection to a heat pump

GLASS & INOX

Model 160 200 300 500 800 1000
Capacity Lt 150 181 276 429 750 933
External diameter cm 60 60 60 70 99 99
Height cm 103.5 123 176 190 177 210
Net weight kg 87 105 151 211 277 342
Insulation thickness cm 5 5 5 5 7 7
Heat exchanger surface m² 1.80 2.62 3.77 6.00 6.55 8.20
Heat exchanger capacity (S1) Lt 9 13 18 29 43 54
Heat losses kW / 24h 1.4 1.5 1.7 2.5 3.2 3.5
Maximum operating temperature °C 95 95 95 95 95 95
Energy class class B B B C C C

With 2 Heat Exchangers

for connection to a heat pump and solar collectors

GLASS & INOX

Model 200 300 500 800 1000
Capacity Lt 184 272 431 746 919
External diameter cm 60 60 70 99 99
Height cm 123 176 190 177 210
Net weight kg 102 164 212 294 346
Insulation thickness cm 5 5 5 7 7
Heat exchanger surface (S1) m² 1.65 3.12 4.21 4.54 6.18
Heat exchanger surface (S2) m² 0.64 1.14 1.51 2.44 3.66
Χωρητικότητα εναλλάκτη θερμότητας (S1) Lt 8 15 21 30 40
Heat exchanger capacity (S2) Lt 3 6 7 16 24
Heat losses (ΔT 45K) kW / 24h 1.5 1.7 2.5 3.2 3.5
Maximum operating temperature °C 95 95 95 95 95
Energy class class B B C C C

Sockets

GLASS & INOX

160 200 300 500 800 1000
Exchanger inlet - outlet 1" 1" 1" 1" 1" 1"
Cold water inlet – Hot water outlet 1" 1" 1" 1" 1 1/2" 1 1/2"
Recirculation 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
Sensors 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"
Electric Heat element socket 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2"

It is possible to manufacture boilers with larger capacities upon request—ranging from 1,500 to 9,000 liters.

Boiler-room water heaters do not include an electric heating element.

* O παραπάνω πίνακας είναι ενδεικτικός και διαφοροποιείται ανάλογα με τις ανάγκες κάθε εγκατάστασης